- Its sleek, ergonomic design with anti-slip grip comes standard with a highly visible backlit display making it the handheld choice of Journeymen technicians in the field.
- Stores up to 20,000 data points which is easily downloaded to your company computer for analysis via the USB interface.
- The optional software allows the users to view real-time data graphically formated on their company computer
- For your convenience the anemometer keeps track of its own calibration cycle and reminds you when it is due for calibration*.
- The CLIMOMASTER 6501-CE measures pressure and features an analog output.
- Equipped with an automatic atmospheric pressure compensation function.
- When the direction of the airflow is known, choose a UNIdirectional probe.
- When the direction of the airflow is unknown or turbulent, choose an OMNIdirectional probe.
PROBE PART # | 6531-2G | 6541-2G | 6561-2G | 6542-2G | 6533-2G | 6543-2G | 6551-2G | 6552-2G |
Air Velocity Range (FPM) | 2 to 6000 | 2 to 6000 | 2 to 9840 | 2 to 6000 | 2 to 1000 | 2 to 1000 | 2 to 6000 | 2 to 6000 |
Airflow Directivity | UNI | UNI | UNI | Omni | Omni | Omni | Omni | Omni |
Probe Type | Rod | Rod | Rod | Needle | Spherical | Spherical | Miniature | Miniature |
Air Velocity | O | O | O | O | O | O | O | O |
Temperature | O | O | O | O | O | O | ||
Relative Humidity | O | O |
Measurement Specifications | |
Differential Pressure | |
Range | -5 to 5 kPa |
Resolution | 0.01 kPa |
Accuracy | ±3% of READING or ±0.01 kPa whichever is greater |
General Specifications | |
Analog Output | DC 0 to 1 V |
Interface | USB / Printer |
Datalogging | Stores up to 20000 measurement data |
Power Supply | 6 × AA Batteries or AC Adapter (AC 100 to 240 V , 50/60 Hz) |
Weight | 0.9 lbs (400 g) |
Operating Environment | 41 to 104°F (5 to 40°C) with no condensation |
Storage Environment | 14 to 122°F (-10 to 50°C) with no condensation |
Standards | CE-mark |
Warranty | 2 year |
What’s Included | Meter, Operation manual, Carrying case, USB cable, AA batteries, 2m probe cable |
6501-0E | 6501-CE | |
Differential Pressure | O | |
Analog Output | O | |
USB Interface | O | O |
Printer Interface | O | O |
Measurement Specifications | |
Air Velocity | |
Range | 2 to 9840 FPM (0.01 to 50 m/s) |
Resolution | 1 FPM (0.01 m/s) |
Accuracy | +/- 2% of READING or +/- 0.015 m/s (+/- 3 FPM) whichever is greater |
Temperature | |
Range | -4 to 158°F (-20 to 70°C) |
Resolution | 1°F (0.1°C) |
Accuracy | +/- 1°F (+/- 0.5 °C) |
Relative Humidity | |
Range | 2.0 to 98.0 %RH |
Resolution | 0.1% |
Accuracy | ±2.0% (at range of 2 to 80%) ±3.0% (at range of 80 to 98%) |
General Specifications | |
Operaing Environment | -4 to 158°F (-20 to 70°C) with no condensation |
Storage Environment | 14 to 122°F (-10 to 50°C) with no condensation |
Standards | CE-mark |
Warranty | 2 year |
Standard Accessories | Probe, NIST Certificate |
6531-2G | 6541-2G | 6561-2G | 6542-2G | 6533-2G | 6543-2G | 6551-2G | 6552-2G | |
Air Velocity Range (FPM) | 2 to 6000 | 2 to 6000 | 2 to 9840 | 2 to 6000 | 2 to 1000 | 2 to 1000 | 2 to 6000 | 2 to 6000 |
Airflow Directivity | UNI | UNI | UNI | Omni | Omni | Omni | Omni | Omni |
Probe Type | Rod | Rod | Rod | Needle | Spherical | Spherical | Miniature | Miniature |
Air Velocity | O | O | O | O | O | O | O | O |
Temperature | O | O | O | O | O | O | ||
Relative Humidity | O | O |
- User Manual
- Data Sheet (English)
- Data Sheet (Spanish)
- Probe Engineering Drawings
- Anemometer Selection Guide
- Evolution of Hotwire Probes
- The Relationship Between Air Velociy, Temperature and Pressure
- Measuring Airflow in the Cleanroom
- Software Manual
- Climomaster USB Driver
The principles behind all hot-wire anemometers may be the same, but the quality varies. Simply put, with our temperature compensation sensor, our Climomaster is the most accurate with an accuracy of +/- 2%. This is due to several factors: 1) We calibrate the temperature compensation sensor, as well as the velocity sensor. Other manufacturers only calibrate the velocity sensor. 2)We use special high-quality materials, like our platinum sensors, that increase accuracy. 3) Our manufacturing facility uses not 1, but 4 specialized wind tunnels to test and calibrate our anemometers. These wind tunnels include a low velocity tunnel, high tunnel velocity and a variable temperature wind tunnel. 4) We’ve been making anemometers for over 80 years. During that time we’ve perfected our knowledge and refined our manufacturing process to produce a research-grade instrument.
You can measure clean air between -4 and 158°F (-20 to 70°C) in an environment with no visible condensation. (Please note: the temperature range given is for the probes)
No, these are thermal anemometers that generate heat when in operation; if you expose them to a flammable gas it could cause a fire or explosion. Corrosive or caustic gases, such a chlorine, will damage the sensor on contact. While it is possible to use the instrument in a non-flammable, non-caustic gases the instrument is not calibrated for these gases and it will not measure airflow accurately.
No. Unfortunately these options are built into the main unit and must be ordered with the unit. They cannot be added later.
Windows XP (32-bit only), Vista, & Windows 7. (Please Note: Anemomaster Professional comes with software. It is available as an option for the Climomaster.)
The unit ships in a hard carrying case and includes a probe connector cable, 6 x AA batteries, and a NIST traceable calibration certificate. Note: The main body does not come with a probe, but we do have combo part numbers available that include a probe.
The Climomaster probes use a smart technology that keeps the calibration data on a small chip inside each probe. This means you can swap out the probes freely in the field without needing to recalibrate either the probes or the main unit. You can also swap out the probe cable in the field if you need different lengths for different applications.